Core and chip tray photos. Import › Photos takes a folder or a drop of tray photos (JPEG, PNG or WebP; HEIC is refused for now) and matches each one to a hole and a depth from its file name, a CSV index or the drillhole log. Check the matches in the table, fix or skip a row, then import; an interrupted import carries on where it stopped. The original photos are copied into the project folder unchanged.
Every hole has a Photos tab with its trays in depth order, dry and wet, and a photo rail beside the interval tables follows the cursor. Collar straightens and crops each photo on this device; the viewer shows Original or Corrected, and Adjust moves the corners, rotates and sets the white balance. A suggested crop is never exported or printed as corrected until someone accepts it. In field mode the Log step has a Tray photo button (Chip tray photo for chip trays).
Settings › Photos holds the tray profiles (HQ, NQ, PQ and chip trays, plus your own), the file naming patterns and the size of this device's photo cache. Eight new rules (R120 to R123 and R125 to R128) put photo problems in the review queue, such as a photo of a hole that was deleted.
Export › Photos writes the photos with their index for Collar, Datarock or Micromine, to a folder or a zip, and prints marker sheets: printed markers placed with a tray so Collar can straighten and scale its photo. Export › Reports makes the drillhole log PDF, a fixed layout for one hole or up to 20 at 1:200, 1:500 or 1:1000, with a photo column and photo pages; a hole's header opens it too.
Lab certificates on Import. A certificate dropped on Import (an ALS download, or a sheet with method, unit and detection limit rows above the results) is recognised and offered to Assays, which reads it as a certificate.
Results by lab method. Two lab methods of one element on a certificate, such as Au-AA23 and Au-AA25, are two results, not a duplicate: R93 fires only on a true repeat, the reported value prefers a readable number over an over-range one, and R92 is resolved when the reported value is a number at or above the limit. QAQC charts and judges one of the two on each standard, blank, duplicate and umpire, chosen by the same rule, and shows the other on the point's detail, so nothing is charted or counted twice.
Precedence by standard lab practice. When two lab methods of one generic method both read a sample, the larger fire assay charge is used first and, at one charge, the trace method before the ore-grade one (an over-range trace result still gives way to the ore-grade number); Settings › Labs, methods and precedence changes the order. Gold's default list now puts screen fire assay (FA-SCR) first and aqua regia ICP-MS above cyanide leach and four acid. A screen fire assay's calculated total is its result; its fraction assays and weights are not imported as results.
Project format 3. New projects, and folders of CSVs adopted as projects, are created at format 3 and open in Collar 1.1.0 or newer. A project made by Collar 1.0 keeps working as it is; to add photos, upgrade it once from Settings › Project details. The upgrade is one logged operation, keeps everything and cannot be undone. It names any device that last used an older Collar: Collar 1.0 cannot open the project afterwards and says to update.
Settings, certificates and holds are saved. Settings, lab certificates (their results, original files and quarantined lines), holds, releases and QAQC report narratives are saved to the project folder like every other edit and reach other devices with the next sync. In Collar 1.0 they were kept only until the tab closed: check the Settings and Assays of projects you edited in 1.0. A project made by Collar 1.0 saves them once upgraded to format 3 (Settings › Project details, once per project, after every device has Collar 1.1.0); until then Settings and Assays say “Upgrade the project first”.
Holds that QAQC places are worked out from the results, not stored: a failed certificate method stays held until someone releases it, and a release stands until a failure appears that it did not cover, when the method is held again with the new finding named. A partial fix does not ask again. tables/hold.csv lists only the holds and releases people made. Devices on the same version of Collar with the same results files agree on every hold; a version that changes the QAQC defaults says so in its release notes.
While a certificate’s results file has not reached a device, that device keeps the certificate’s holds as its last full check there found them, marked “Not checked on this device” in Assays and Review (none if the file was never on that device), and refuses exports with assay results and the validation report until the file arrives.
Help on every screen: Help opens the topic for the screen you are on, with Back to where you were, and every screen and rule has its own help, readable offline.
Collar cloud is our hosted service for companies; your project folder also still works exactly as before.