R113 · Lab method not mapped to a generic method

Warning Project

Precedence, CRM limits and QAQC all work on generic methods (FA, 4A-ICPMS) so that two labs' codes for the same analysis compare. A lab method in use with no mapping is compared with nothing and may be ranked wrongly in precedence.

01

What it checks

Reports each lab and lab method used on a certificate that has no row in method_map linking it to a generic method.

02

Why it matters

Precedence, CRM limits and QAQC work on generic methods so that two labs' codes for the same analysis compare. An unmapped method is compared with nothing and may be ranked wrongly in precedence.

03

What to do

Map the lab method to its generic method, such as FA or 4A-ICPMS, using the lab's method schedule.