Collar › Rules › Project › R113
Rules · Project
R113 · Lab method not mapped to a generic method
Warning Project
Precedence, CRM limits and QAQC all work on generic methods (FA, 4A-ICPMS) so that two labs' codes for the same analysis compare. A lab method in use with no mapping is compared with nothing and may be ranked wrongly in precedence.
What it checks
Reports each lab and lab method used on a certificate that has no row in method_map linking it to a generic method.
Why it matters
Precedence, CRM limits and QAQC work on generic methods so that two labs' codes for the same analysis compare. An unmapped method is compared with nothing and may be ranked wrongly in precedence.
What to do
Map the lab method to its generic method, such as FA or 4A-ICPMS, using the lab's method schedule.
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.