When the project says every tray is photographed (Settings, Photos expected), each metre of cored and logged hole should have a dry photo: it is the record a reviewer or a later geologist checks the logging against, and the core itself may be gone. The rule lists, per hole, the cored ranges with lithology logged that no current dry photo covers.

01

What it checks

When Photos expected is on (Settings › Photos), reports per hole the cored ranges (core runs) with a lithology code logged that no current dry photo covers. A photo with no condition counts as dry; a wet photo does not.

02

Why it matters

The dry photo is the lasting record of the core that a reviewer checks the logging against, often after the core has been split, sampled or thrown away. A missing tray is easiest to fix while the trays are still at the shed.

03

What to do

Photograph or import the missing trays, or attach the file to the tray in the Photos tab. Turn Photos expected off if the project does not photograph every tray.