Collar
Open the demo

Collar › Rules › Intervals › R51

Rules · Intervals

R51 · Lithology percentages do not add to 100

Warning Intervals

When an interval is logged as two lithologies with percentages, the two shares describe the whole interval and must add to 100. Any other total means one percentage is a typo, and grade-by-lithology summaries weight the interval wrongly.

01

What it checks

In the lithology table, when both lith1_pct and lith2_pct are filled, reports a row whose sum differs from 100 by more than the tolerance.

02

Why it matters

The two shares describe the whole interval. Any other total means one percentage is a typo, and grade-by-lithology summaries weight the interval wrongly.

03

What to do

Correct the percentage that is wrong from the logging sheet.

04

Settings

SettingDefaultWhat it means
Allowed difference from 1000.5 %The allowed difference from 100, in percent (default 0.5). It absorbs rounding; raise it only if your loggers estimate percentages coarsely.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.