Collar
Open the demo

Collar › Rules › QAQC › R101

Rules · QAQC

R101 · CRM bias: two of three outside the warning limit

Warning QAQC

Two of three consecutive CRM results outside the inner limit on the same side are a bias, not chance: the lab is drifting high or low for that method. No single result fails, but the batch's grades are shifted and the lab should be asked.

01

What it checks

Takes each CRM, element and method on a certificate in certificate order and reports when two of three consecutive results fall outside the inner limit on the same side.

02

Why it matters

Two of three outside on one side is a bias, not chance: the lab is drifting high or low. No single result fails, but the grades in the batch are shifted.

03

What to do

Raise it with the lab and watch the next batches. Acknowledge with a reason once the lab has explained or corrected the drift.

04

Settings

SettingDefaultWhat it means
Use SD limits when the library has an SD (else ± % of certified)OnWhen on (default), limits are set in standard deviations wherever the CRM library has an SD for the value; otherwise they are a percentage of the certified value.
Outer (fail) limit in SD3 SDThe fail limit, in standard deviations from the certified value (default 3). This rule does not use it; R100 does.
Outer (fail) limit in % of certified10 %The fail limit as a percentage of the certified value, used when there is no SD or SD limits are off (default 10%). This rule does not use it; R100 does.
Inner (warning) limit in SD2 SDThe warning limit, in standard deviations from the certified value (default 2).
Inner (warning) limit in % of certified5 %The warning limit as a percentage of the certified value, used when there is no SD or SD limits are off (default 5%).

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.