Collar
Open the demo

Collar › Rules › Collar › R11

Rules · Collar

R11 · Collar far from its planned position

Warning Collar

Rigs set up within a few metres of the peg. A drilled collar tens of metres from its planned position is either a moved hole that needs a note, or a coordinate entered against the wrong hole id.

01

What it checks

For each hole whose preferred set is not the planned one, measures the horizontal distance from the planned coordinate set to the preferred set. A distance beyond the tolerance is reported on the preferred set.

02

Why it matters

Rigs set up within a few metres of the peg. A collar tens of metres from its plan is either a hole that was moved, which the report should explain, or a pickup entered against the wrong hole id.

03

What to do

Check the pickup and the drilling records. If the coordinates belong to another hole, move them. If the hole was moved on purpose, acknowledge with a reason so the move is recorded.

04

Settings

SettingDefaultWhat it means
Allowed horizontal distance from the plan10 mThe allowed horizontal distance between plan and actual, in metres (default 10 m). Raise it where pads are often shifted for access or heritage; lower it where you expect tight set-outs.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.