Rules · Collar
R16 · Precollar or casing deeper than EOH
Blocker Collar
A precollar or casing cannot be deeper than the hole. When it is, either EOH or the depth is wrong, and the drill-method split, core-run checks and magnetic-survey checks (R28, R54, R60) are all judged against the wrong depth.
What it checks
Reports a collar whose precollar_depth or casing_depth is deeper than its eoh_depth. Holes without an EOH are skipped here (R4 reports them).
Why it matters
A precollar or casing cannot go deeper than the hole. When they disagree, the drill-method change (R54), core runs above the precollar (R60) and magnetic shots inside casing (R28) are all judged against the wrong depth. It is a blocker.
What to do
Check the driller's plods. Usually EOH is wrong (the precollar depth was entered as EOH) or the precollar or casing depth was typed into the wrong column. Fix whichever value is wrong.
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.