Collar
Open the demo

Collar › Rules › Core runs › R59

Rules · Core runs

R59 · Core size steps up down the hole

Warning Core runs

A diamond hole can only reduce core size as it deepens (PQ to HQ to NQ): a larger bit cannot pass a smaller casing. A size that grows down the hole is a logging or data-entry error, and it changes sample weights and recovery expectations.

01

What it checks

In drill_method, follows the diameter down each hole and reports an interval whose core size is larger than the size above it in the size order. Sizes not in the order are ignored.

02

Why it matters

A diamond hole can only reduce core size as it deepens, because a larger bit cannot pass a smaller casing. A size that grows down the hole is a logging error, and it changes sample weight and recovery expectations.

03

What to do

Check the drilling report for the actual size changes and correct the diameter.

04

Settings

SettingDefaultWhat it means
Core sizes, largest firstPQ, HQ, NQ, BQ, AQCore sizes from largest to smallest (default PQ, HQ, NQ, BQ, AQ). A diameter is matched by how it starts, so HQ3 counts as HQ. Add other sizes your drillers use, in order.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.