01
What it checks
In the structure table, reports an alpha outside 0 to 90°, a beta outside 0 to 360°, or either value that is not a number.
02
Why it matters
Alpha is measured from the core axis and beta around the core. Values out of range cannot be converted to a true dip and dip direction, so the measurement is unusable and it blocks export.
03
What to do
Check for alpha and beta swapped, or a dip and dip direction entered in their place, and correct the value from the structure log.
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.