Collar
Open the demo

Collar › Rules › Samples › R72

Rules · Samples

R72 · Standard or blank set up wrongly

Blocker Samples

A CRM result can only be judged against the certified value of the right standard: without a CRM code, or with a code the library does not hold, the QAQC verdict (R100) cannot run. A standard or blank carrying a downhole interval is usually a register row shifted by one, so a real sample lost its interval (warning).

01

What it checks

For standards (crm and standard_inhouse), reports a missing crm_code or a code not in the CRM library, as a blocker. For standards and blanks, reports a downhole interval, as a warning.

02

Why it matters

A CRM result is judged against the certified value of the right standard; without a known code R100 cannot run. A standard or blank carrying an interval usually means register rows shifted by one, so a real sample lost its interval.

03

What to do

Enter the CRM code from the sample sheet, or add the standard to the CRM library from its certificate. For an interval on a QC sample, check the rows around it for a shift and move the interval to the right sample.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.