Collar › Rules › Samples › R79
Rules · Samples
R79 · QC insertion rate below target
Warning Samples
QAQC only proves the data if standards, blanks and duplicates go in at the planned rate throughout the program, not just on average. A run of 100 register samples with fewer than the target share of a QC type is a stretch of assays that cannot be checked as well as the rest. (Per-certificate rates are R106.)
What it checks
Walks the register in sample id order with a sliding window of the set size. For each QC type, reports each stretch where a window holds fewer of that type than the target share.
Why it matters
QAQC only proves the data if QC samples go in at the planned rate throughout the program. A stretch with too few is a run of assays that cannot be checked as well as the rest. Per-certificate rates are R106.
What to do
Insert the short QC type in the next batches and, where the assays matter, submit extra QC for the affected stretch. If the stretch is historic or was never assayed, acknowledge with a reason.
Settings
| Setting | Default | What it means |
|---|---|---|
| Insertion target per QC type | [object Object] | Target share of the register per QC type, in percent (defaults: crm 6, blank_coarse 2, blank_pulp 2, field_dup 2, coarse_dup 2, pulp_dup 2, umpire 4). Set 0 for a type your program does not use. |
| Sliding window, samples | 100 | The number of register samples in each window (default 100). A smaller window finds short lapses in insertion; a larger one smooths over them. |
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.