Collar
Open the demo

Collar › Rules › Results › R93

Rules · Results

R93 · Duplicate result

Blocker Results

One certificate cannot report two values for the same sample, element, lab method, role and repeat: precedence would have to pick one at random. Two lab methods that share one generic method (Au-AA23 and Au-AA25, both fire assay) are two results, not a duplicate. A duplicate usually means the same file was loaded twice into one certificate or a repeat column was mapped as the original.

01

What it checks

On each certificate, reports a second result for the same sample, element, lab method, role and repeat. Two lab methods that share one generic method (Au-AA23 and Au-AA25, both fire assay) are two results, and precedence picks between them.

02

Why it matters

One certificate cannot report two values for one key; precedence would have to pick one at random, so this blocks export.

03

What to do

Usually the same file was loaded twice into one certificate, or a repeat column was mapped as the original. Re-import the certificate with the right mapping.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.