Collar › Rules › Results › R99
Rules · Results
R99 · Negative result
Warning Results
A negative grade is impossible except for a few measurements (loss on ignition, magnetic susceptibility). Elsewhere it is a below-detection convention (−0.01 for <0.01) that was not declared, and averaging it as a number pulls composites down.
What it checks
Reports an uncensored numeric result below zero, except for elements in the exempt list.
Why it matters
A negative grade is impossible for most elements. It is usually an undeclared below-detection convention, such as −0.01 for <0.01, and averaging it as a number pulls composites down.
What to do
Declare the lab's negative convention in the import mapping so the values read as below detection, then re-import. If negatives are real for that measurement, add it to the exempt list.
Settings
| Setting | Default | What it means |
|---|---|---|
| Elements that may be negative | LOI, MagSus, MS | Elements that may legitimately be negative (default LOI, MagSus and MS). Add any other measurement that can be negative. |
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.