Rules · Survey
R22 · Station depth outside the hole
Blocker Survey
A station above the collar or below the end of hole is a depth typo, a wrong EOH, or a station from another hole. Within a small tolerance past EOH it is usually rounding (warning); beyond it, it blocks export because the trace would extend past the hole.
What it checks
Reports any station with a negative depth, and any station deeper than the hole's EOH. A station past EOH but within the tolerance is a warning; beyond it, a blocker.
Why it matters
A station above the collar or below the end of hole cannot be part of the trace. Beyond EOH the trace would run past the hole, so export is blocked. Usually it is a depth typo, a wrong EOH or a station from another hole.
What to do
Compare the station depth with EOH and the survey sheet. Fix a typo, correct EOH if the hole is actually deeper, or reject the station. A last shot just past EOH from rounding can be acknowledged with a reason.
Settings
| Setting | Default | What it means |
|---|---|---|
| Allowed depth past EOH (warning only) | 0.5 m | How far past EOH, in metres, a station is only a warning (default 0.5 m). Beyond it the finding is a blocker. Keep it small: the last shot is normally taken at or just above EOH. |
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.