Rules · Survey
R29 · Magnetic readings disagree with the model
Warning Survey
Modern tools record the field strength, magnetic dip and gravity they measured. Where these differ from the geomagnetic model at the hole's place and date, the tool was disturbed (magnetic rock, steel, a bad calibration) and its azimuth cannot be trusted.
What it checks
For accepted stations that record total field, magnetic dip or gravity, compares each value with the bundled geomagnetic model at the hole's position and the run date. Values outside the tolerance are reported. Runs without a date are skipped.
Why it matters
When the tool's own readings differ from the model, it was disturbed by magnetic rock, steel or a bad calibration. Its azimuth cannot be trusted, even when the trace looks smooth.
What to do
Look for a pattern: a zone of magnetic rock such as magnetite or pyrrhotite, or a whole run off by the same amount (calibration). Reject the affected stations or rely on a gyro run; acknowledge with a reason where a reading is kept.
Settings
| Setting | Default | What it means |
|---|---|---|
| Allowed total-field difference | 300 nT | Allowed difference in total field strength, in nanotesla (default 300 nT). Tighten it if your contractor's tools are well calibrated. |
| Allowed magnetic-dip difference | 0.3 ° | Allowed difference in magnetic dip, the inclination of the field, in degrees (default 0.3°). Larger differences point to local magnetic disturbance. |
| Allowed gravity difference | 0.02 g | Allowed difference in measured gravity, in g (default 0.02 g). A large gravity error means the tool was moving or its accelerometers are faulty. |
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.