R24 · Dip or azimuth out of range

Blocker Survey

Dip must be between −90 and 90 and azimuth between 0 and 360 (360 is stored as 0). Anything else is a typo, a grad/degree mix-up or a value in the wrong column, and the trace computed from it is meaningless.

01

What it checks

Reports a dip outside −90 to 90 and an azimuth (raw or grid) outside 0 to 360, with 360 read as 0. A survey angle that is not a number at all is reported here too.

02

Why it matters

An angle out of range is a typo, a grad and degree mix-up or a value in the wrong column. The trace computed from it is meaningless, so it blocks export.

03

What to do

Check the survey file for shifted columns or a units problem and fix the value at the source. If the reading cannot be recovered, reject the station.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.