Collar
Open the demo

Collar › Rules › Survey › R25

Rules · Survey

R25 · Mixed dip signs

Blocker Survey Hole types exempt by default: TR, CO

Collar stores dips negative down. Tables assembled from several sources often mix conventions: some holes positive down, some negative, or a sign that flips part-way down one hole. A surface hole cannot dip upwards, so positive dips beside negative ones are a convention error that sends the trace into the sky. Flip the hole or the table.

01

What it checks

Looks at the sign of accepted dips across the survey table. A hole with both signs is a blocker. A surface hole with only positive dips is a blocker when other holes are negative, and a warning when none are. Underground hole types may dip up.

02

Why it matters

Collar stores dips negative down. Tables built from several sources often mix conventions, and a surface hole cannot dip upwards, so a positive dip sends the trace into the sky and places every intercept above ground.

03

What to do

Find which source used positive-down dips and flip them. Collar offers: Flip the dips of this hole, and, when no hole is negative, Flip every dip in the survey table. A hole with mixed signs needs its stations checked one by one.

04

The fixes Collar offers

  • Negate the dips of one hole's stations, or of the whole survey table.
05

Settings

SettingDefaultWhat it means
Hole types exempt from this ruleTR, COHole types this rule skips (default TR and CO, trenches and costeans, which have no downhole survey). Add other types that are not drilled holes. These are the hole-type exemptions in Settings › Rules and parameters.
Hole types drilled from underground (may dip up)UG, UGDDHole types drilled from underground, which may dip upwards (default UG and UGDD). Their positive dips are not reported unless one hole mixes signs. Add your project's underground codes.

From Collar 1.1.0's rule catalogue. The same text is in the app under Help.