Rules · Survey
R25 · Mixed dip signs
Blocker Survey Hole types exempt by default: TR, CO
Collar stores dips negative down. Tables assembled from several sources often mix conventions: some holes positive down, some negative, or a sign that flips part-way down one hole. A surface hole cannot dip upwards, so positive dips beside negative ones are a convention error that sends the trace into the sky. Flip the hole or the table.
What it checks
Looks at the sign of accepted dips across the survey table. A hole with both signs is a blocker. A surface hole with only positive dips is a blocker when other holes are negative, and a warning when none are. Underground hole types may dip up.
Why it matters
Collar stores dips negative down. Tables built from several sources often mix conventions, and a surface hole cannot dip upwards, so a positive dip sends the trace into the sky and places every intercept above ground.
What to do
Find which source used positive-down dips and flip them. Collar offers: Flip the dips of this hole, and, when no hole is negative, Flip every dip in the survey table. A hole with mixed signs needs its stations checked one by one.
The fixes Collar offers
- Negate the dips of one hole's stations, or of the whole survey table.
Settings
| Setting | Default | What it means |
|---|---|---|
| Hole types exempt from this rule | TR, CO | Hole types this rule skips (default TR and CO, trenches and costeans, which have no downhole survey). Add other types that are not drilled holes. These are the hole-type exemptions in Settings › Rules and parameters. |
| Hole types drilled from underground (may dip up) | UG, UGDD | Hole types drilled from underground, which may dip upwards (default UG and UGDD). Their positive dips are not reported unless one hole mixes signs. Add your project's underground codes. |
From Collar 1.1.0's rule catalogue. The same text is in the app under Help.